Litho Neutron Density Caliper (LNDC)

LWD Triple Combo Tool

Product Overview

The LNDC tool delivers real-time formation density, neutron porosity, borehole caliper, and azimuthal imaging—enabling enhanced lithology identification, reservoir evaluation, and wellbore stability analysis while drilling. As a key component in a “triple combo” (with gamma ray and resistivity), it supports accurate formation characterization and reserves assessment.

Key Features

  • 4 3/4" collar size with compact 13 ft design
  • Integrated He-3 neutron detectors for ultra-sensitive formation response
  • Measures bulk density, photoelectric factor (PEF), and standoff caliper
  • 16-sector azimuthal density imaging for wellbore geometry and lithofacies recognition
  • Near-bit neutron/density measurements corrected for environmental effects

Applications & Drilling Scenarios

  • Real-time petrophysical evaluation in unconventional or complex reservoirs
  • Quantitative understanding of porosity, mineralogy, and hydrocarbon types
  • Wellbore stability monitoring for high-angle or unstable formations
  • Combined with gamma and resistivity for complete triple combo logging

Advantages

  • He-3 detector placement improves signal-to-noise response
  • Short bit-to-detector offset enables early decision-making
  • Calibrated for environmental conditions, reducing post-processing corrections

Compatibility

Compatible with common MWD/LWD telemetry systems and can be configured in conjunction with resistivity tools.

Technical Specifications

Tool Performance Specifications

Measurement Type Range / Performance
Azimuthal Litho-Density Range: 1.5–3.1 g/cc; PEF: 1–7 B/e
Azimuthal Litho-Density Accuracy: ±0.015 g/cc; ±0.25 B/e
Azimuthal Litho-Density Repeatability (180 ft/hr): ±0.01 g/cc @ 2.2 g/cc
Azimuthal Litho-Density Repeatability (180 ft/hr): ±0.25 B/e @ 3 B/e
Neutron Porosity Range: -5 to 100 p.u.
Neutron Porosity Accuracy: ±0.5 p.u. (<10 p.u.); ±5% (10–40 p.u.)
Neutron Porosity Repeatability (180 ft/hr): ±1 p.u. @ 20 p.u.
Caliper / Standoff Range: 0–2"
Caliper / Standoff Accuracy: ±0.1"

Mechanical Specifications

Feature Specification
Collar OD 4 3/4"
Length 13 ft
Detector Type He-3 thermal neutron detectors (external mounted)
Azimuthal Resolution 16 sectors